Sensor specifications |
Environmental, regulatory and physical |
Operating temperature range –20 to +60 °C (–5 to +140 °F) |
Storage temperature range –20 to +45 °C (–5 to +115 °F) for less than one month |
–20 to +35 °C (–5 to +95 °F) for less than six months |
The above temperature/time limits are to avoid excessive self-discharge of the battery. |
Charging temperature, |
range (sensor/charger) |
0 to 40 °C (32 to 105 °F) |
Humidity 95% non-condensing |
Altitude Up to 2 000 m (6 560 ft) |
Drop test 1.8 m (6 ft) in accordance with MIL-STD-810G |
Sensor IP rating IP65 (Dust and water ingress protection testing standard.) |
Radio approvals Europe (CE), USA (FCC), Canada (IC) |
CE Mark CE-approved |
Dimensions 45 x 45 x 135 mm (1.8 x 1.8 x 5.3 in.) |
Mass 200 g (7 oz) |
Power |
Sensor power source Rechargeable lithium battery, 3.7 V DC. 0.14 Ah |
Battery lifetime A full working day under normal usage reducing to half a working day when an external |
sensor is being used. |
Charger Input 100 to 240 V AC, 0.4 A, 47 to 63 Hz |
Measurement and analysis functions |
Internal sensor ±5%: 5 Hz to 3 000 Hz |
frequency range ±10%: 3 Hz to 5 000 Hz |
±3 dB: 1.4 Hz to 10 000 Hz |
The response is attenuating (3 dB down) at both frequencies |
Overall velocity 10 Hz to 1 kHz up to 55 mm/s RMS |
Bearing condition SKF patented Enveloped acceleration |
gE Bands 2 and 3, up to 20 gE True Peak-to-Peak |
Temperature Built in infrared (IR) sensor |
Capable of measuring outside the QuickCollect operating temperature range and up to |
100 °C for short periods. |
Vibration Time Waveforms Acceleration (g), Enveloped acceleration (gE) |
Sample rates: 256 Hz to 25.6 kHz |
Sample lengths: 256 to 8 192 samples |
Spectrum/FFT Acceleration (g), Velocity (mm/s), Enveloped acceleration (gE) |
Maximum frequency: 100 Hz to 10 kHz |
Resolution: 100 to 3 200 lines |