Description:
• Fully Safety jaw | |
• Ergonomic over-molded body gives convenient one-hand operation | |
• Large easy-to-read display with 0.01A resolution | |
• Accurate reading with True RMS | |
60/600/1000A auto-ranging | |
• Long battery life | |
• Safety Standard | |
IEC 61010-1 CAT IV 300V / CAT III 600V | |
AC A | 60.00/600.0/1000A (Auto-ranging) |
±1.5%rdg±4dgt [45 - 65Hz] | |
±2.0%rdg±5dgt [40 - 1kHz] | |
AC V | 60.00/600.0V (Auto-ranging) |
±1.0%rdg±2dgt [45 - 65Hz] (600V) | |
±1.5%rdg±4dgt [40 - 1kHz] (60/600V) | |
DC V | 60.00/600.0V (Auto-ranging) |
±1.0%rdg±3dgt (60V) | |
±1.2%rdg±3dgt (600V) | |
O | 600.0O/6.000/60.00/600.0kO (Auto-ranging) |
±1.0%rdg±5dgt (600O) | |
±2.0%rdg±3dgt (6/60/600kO) | |
Continuity buzzer | 600O(Buzzer sounds below 90O) |
Conductor size | Ø33mm max. |
Applicable standards | IEC 61010-1 CAT IV 300V, CAT III 600V Pollution degree 2 |
IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033, | |
IEC 61326-2-2(EMC), IEC 60529 IP 40, EN50581(RoHS) | |
Power source | R03/LR03 (AAA) (1.5V) × 2 |
Continuous measuring time | Approx.170 hours |
(When R3 is used)(NCV_LED:off) | |
(Auto power save : approx. 10 minutes) | |
Dimensions | 204(L) × 81(W) × 36(D)mm |
Weight | 220g Approx. (including batteries) |
Included Accessories | 7066A (Test leads) |
9079 (Carrying case), R03 (AAA) × 2, |